Main Distribution Frames
See Also: |
INDEX :
XL-033/034 Product Description
AS-MDFNT36 MAIN DISTRIBUTION FRAME
DDF
with alum frame
Wall mouted Alum Frame
200pairs
mounting frame
| XL-033/034 |
|
1、The frame is made of shaped steel
, it looks nice in shape and construction; Floor frame; |
| AS-MDFNT36 MAIN DISTRIBUTION FRAME
|
| Main distribution frame is applicable by various
large-capacity programme controlled switching systems, it is used to connect
inside and outside cables, patch cords, to test and protect inner equipments
and people’s lives. Suitable for large and small-capacity programme controlled
telephone exchanges. |
|
![]() ![]() |
|
Wall mounted two alum barres frame for DDF/MDF blocks |
![]() ![]() ![]() |
Type: AS-DDF-MK 16 |
Product Description ... |
| Type: AS-MDF112A-C Product Name: CONNECTION BLOCK |
Product Description ... ![]() 1?Test connection block is mounted on the horizontal side of the MDF used for termination between jumper wire and internal exchange cable, 2?It is a normally closed type contact, when the disconnection plug is inserted into the test block, the internal cable and jumper wire will be disconnected, the test plug with cord can be used to test internal line and external line independently, 3?The protection plug can be used to lable and pretect important or special subscribe line, 4?Each unit of test connection block is of max capacity of 128L, which is composed of horizontal module, panel, connection axes as well as dustproof cover etc, both of the internal side and jumper wire side have the cross board. 5?The performance of anti-burn: PPT(UL94V-0) or anti-burn ABS(UL94V-0), combustibility achieved GB/T 5169.7-1985 standard |
| Type: AS-MDF112A-P Product Name: PROTECTOR BLOCK |
Product Description ... ![]() 1?Protection connection block is mounted on the vertical side of MDF, which is used for termination between external line cable and jumper wire, it can protect the MDF against over voltage and over current, 2?Perfect and reliable over-voltage and over-current protection with sound and light alarm, and self resulming fail protection; (With Protector unit) 3?it is designed in such structure: the line side and the jumper wire side is disconnected before the protector is inserted into the protection connection block, they will be connected after inserting the protector, 4?when the line side suffer danger, only pull out the protector, the exchange side will be disconnected with the outside line, 5?The performance of anti-burn: PPT(UL94V-0) or anti-burn ABS(UL94V-0), combustibility achieved GB/T 5169.7-1985 standard 6?Each protection block has termination capacity of 100 pairs and consist of vertical module, 100 alarm plug, back-mounting frame etc. both the outside line and the jumper wire side have the wiring board. |
|
|